Win the world® Computer temperature measurement of mass concreteFirst line communicationsystem |
|||||
Real time remote monitoring£¬Compatible wired¡¢wireless¡¢£Ç£Ð£Ò£ÓEtc.¡¡ |
|||||
¡ôFirst line communication system£º | |||||
|
|||||
¡÷First line communication system diagram |
|||||
|
|||||
¡ôFirst line communication system components£º |
|||||
|
Data adapter£º |
||||
Connect all field collectors in series through a data line£¬Basic data transmission distance1.2kilometre£¬Data adapter for data format conversion¡¢relay¡¢control¡¢And provide power to all field devices through data lines¡£The data adapter can be£Õ£Ó£ÂDirect line to computer¡¢It also supports communication with computers through radio stations£¬It also directly supports the adoption ofGPRS-DTUConnect to remote server£¬Make communication unlimited¡£ Battery access point on adapter,As backup power supply,Automatic switching£¬Call self charging),Make the system work by itself even if it is powered off or disconnected from the computer¡£ Each device only needs one data adapter¡£ |
|||||
data collector£º |
|||||
Put on the spot£¬Pluggable on each collector£±¡«£¸Temperature sensors¡£On site inspection and display£¬Data can be uploaded to a computer or remote server¡£The same data line can be connected in series256Field Collector only¡£The power comes from the charge pump technology of data line¡£ Multiple data required for each set of equipment collector£¬It is related to the number of temperature measurement plane points¡£¡¡ |
|||||
Temperature sensor and lead£º |
|||||
Before binding or casting£¬Fix the sensor to the set position and depth in the concrete to be poured¡£Sensor easy to use metal shell protection£¬And long enough¡¢Strong enough lead¡£Lead wire has high temperature resistance¡¢Rigid pulling and breaking compensation function¡£ The sensor has been rectified internally£¬It is not necessary to distinguish the positive and negative poles when plugging into the collector.¡£ ¡¾See also¡¿£ºCalculationLead length¡¢ currencyTemperature sensor¡£ |
|||||
£Ç£Ð£Ò£ÓModular£º |
|||||
£Ç£Ð£Ò£Ó££Ä£Ô£ÕNamely£Ç£Ð£Ò£ÓModular£¬Namely£Ç£Ð£Ò£ÓWireless Internet device¡£Used to communicate field devices with remote servers¡£As long as there is£Ç£Ó£ÍMobile signal available everywhere£¬There is no distance limit for data transmission in this mode¡£ Only one for each set of equipment£Ç£Ð£Ò£ÓModular¡£ Our company provides high-performance remote server£¨Cloud services£©Free for regular customers¡£ Under this mode£¬Users do not need to be equipped with on-site office computers£¬No software installed¡£ Use a mobile phone or computer with internet access to view data in real time¡£ £Ç£Ð£Ò£ÓModules are optional devices£¬Just need£Ç£Ð£Ò£ÓSelect when transmitting¡£ | |||||
¡¡ | ¡¡ | ||||
Relay controller£¨Matching£©£º |
|||||
¨‘Each relay controller can control eight load devices at the same time£¬That is, each relay controller has eight control outputs¡£ ¨‘The load that can be controlled by each path itself is220V3A¡£Larger loads can be controlled by adding AC contactors¡£The load can be any switch type electrical appliance£¬For example, the electromagnetic water valve of circulating water¡¢Steam valve¡¢Power switch relay for heater¡¢Control switch of sprinkler¡¢Power controller of air supply and exhaust fan, etc.¡£ ¨‘Relay output control supporting custom logic related to temperature measurement data £¬Achieve the purpose of automatic maintenance |
|||||
¡¡ | |||||
¡¡ | ¡¡ | ||||
¡¡ | ¡¡ | ||||
¡¡ | ¡¡ | ||||
¡¡ | ¡¡ |
Mass concrete temperature measurement system includes£º Real time remote first line communication system¡¢All wireless temperature measurement system¡¢Timing recording system¡¢Portable recorder¡¢Many kinds of common electronic thermometers£¬Each series£¬Which do you prefer£¿ |
¡óProduct list£º
¡îProduct catalog page
Large concrete temperature measurement system
All wireless system of large concrete temperature measurement
On site timed temperature recorderTF
Timing thermographTW(WIFI)
Cloud service timed temperature recorderTG
Large concreteTemperature and humidityCloud acquisition systemHG
Portable electronic thermograph
General electronic thermometer
Universal temperature sensor
Cloud control relay controllerGR
Cloud acquisition system for piling operation
Comparison of large concrete temperature measurement systems
|
¡óManual and software download£º
User manual
¡¢Demonstration¡¢Pictures, etc.
Software download
|
¡óOnline tools£º
Plane layout(Rectangle class¡¢Circular class)
Elevation layout(Sensor lead calculation)
Online selection/Scheme customization |
¡óInstance document£º
Engineering example
Temperature measurement scheme Download
Related papers |
¡óTesting and certification£º ¡îShandong electronic products inspection institute ¡îNational Key Laboratory sapphire certification |
¡¡ |
◊Jinan
Huanyutong Technology Co., Ltd.All rights reserved©1995-2024 [鲁ICPprepare14034635Number] [Lu public network security 37010402000569Number] |
:635211035 |WeChat public service number:wx_0531hyt_com |Home | Product center | Technical theme | contact us | |
Add friends or email: ¡¡ |
|
|
Wechat service number: |
Call up: |
¡¡ |
Self-help: |
Go to knowledge base |
Online Message |